• Burner Manufacturers, Burner Factory, Supply Burner

Burner

Brand Baina

Product origin Jiangsu Yixing, China

Delivery time 8 weeks

Supply capacity 20 sets/month

1. Provide auxiliary heat for incineration.
2. Make the fuel burn completely.

Burner

1. Working principle

Natural gas/diesel oil is used as combustion-supporting fuel to provide heat for the incineration system to meet the temperature control requirements of the incinerator during incineration.


2. Composition

(1) Gas burner: burner nozzle, UV detector, ignition transformer, combustion fan, air pressure switch, gas filter, gas pressure reducing valve, ignition solenoid valve, high and low pressure switch, safety solenoid valve, leakage detection switch, main fire double solenoid valves, pressure regulating valve, proportional control valve, micro pressure gauge, medium pressure gauge, manual valve and control cabinet etc.


(2) Fuel burner: filter, oil pump, pressure relief valve, fuel double cut-off valve, rotameter, pressure regulating valve, high and low pressure switch, proportional control valve, UV detector, igniter, ignition solenoid valve, ignition pressure regulating valve, combustion fan, air low pressure switch, proportional motor and proportional butterfly valve, atomizing air pipe, pressure gauge, manual valve and control cabinet, etc.


3. Burner output

(1)combustion fuel-nature

burner type     output

4514-10          5814KW

4514-9            4651KW 

4514-8-B       2256KW 

4514-8-A       1337KW 

4514-7       756KW 

4422-8-A        1149KW 

4422-7-B        849KW 

4422-7-A        698KW 

4422-6-B        453KW 

4422-6        384KW 

4422-5        233KW 

4422-4        145KW 


(2)combustion fuel-diesel oil

Burner type    output

5514-10       6512KW 

5514-9       4360KW

5514-8-B       2151KW 

5514-8-A       1279KW 

5514-7       749KW

5422-8-A       1163KW 

5422-7-B        872KW 

5422-7-A        698KW 

5422-6        407KW  

5422-5        267KW  

5422-4        163KW 


(3)Natural gas and diesel are shared

 Burner type    output

6514-9       4360KW  

6514-8-B       2151KW  

6514-8-A       1279KW  

6514-7       749KW  

6422-8-A       1163KW  

6422-7-B       884KW  

6422-7-A       698KW  

6422-6       407KW  

6422-5       267KW  

6422-4       163KW


Factory Show

Production in workshop 2
Team Service
Provide professional training
FAQ
How to determine VOCs treatment process
Depending on the Volume, composition, and concentration of the VOCs,if the volume is small (normally less than 10000Nm3/h) and concentration is high(Calorific value is more than 1000Kcal/Nm3), then the first choice is thermal oxidizer(TO). If the volume is large(more than 5000m3/h) and concentration is small (normally less than 5000mg/m3),then regenerative thermal oxidizer will be considered. If t...more
Product Tag:
Get the latest price? We'll respond as soon as possible(within 12 hours)